114 research outputs found

    Anniversary Paper: Evolution of ultrasound physics and the role of medical physicists and the AAPM and its journal in that evolution

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/134810/1/mp2048.pd

    Three-dimensional ultrasound scanning

    Get PDF
    The past two decades have witnessed developments of new imaging techniques that provide three-dimensional images about the interior of the human body in a manner never before available. Ultrasound (US) imaging is an important cost-effective technique used routinely in the management of a number of diseases. However, two-dimensional viewing of three-dimensional anatomy, using conventional two-dimensional US, limits our ability to quantify and visualize the anatomy and guide therapy, because multiple two-dimensional images must be integrated mentally. This practice is inefficient, and may lead to variability and incorrect diagnoses. Investigators and companies have addressed these limitations by developing three-dimensional US techniques. Thus, in this paper, we review the various techniques that are in current use in three-dimensional US imaging systems, with a particular emphasis placed on the geometric accuracy of the generation of three-dimensional images. The principles involved in three-dimensional US imaging are then illustrated with a diagnostic and an interventional application: (i) three-dimensional carotid US imaging for quantification and monitoring of carotid atherosclerosis and (ii) three-dimensional US-guided prostate biopsy

    Measurement of Carotid Plaque Volume by 3-Dimensional Ultrasound

    Get PDF
    Background and Purpose-Measurement of carotid plaque volume and its progression are important tools for research and patient management. In this study, we investigate the observer variability in the measurement of plaque volume as determined by 3-dimensional (3D) ultrasound (US). We also investigate the effect of interslice distances (ISD) and repeated 3D US scans on measurement variability. Materials and Methods-Forty 3D US patient images of plaques (range, 37.43 to 604.1 mm3) were measured by manual planimetry. We applied ANOVA to determine plaque volume measurement variability and reliability. Plaque volumes were measured with 9 ISDs to determine the effect of ISD on measurement variability. Additional plaque volumes were also measured from multiple 3D US scans to investigate repeated scan acquisition variability. Results-Intraobserver and interobserver measurement reliabilities were 94% and 93.2%, respectively. Plaque volume measurement variability decreased with increasing plaque volume (range, 27.1% to 2.2%). Measurement precision was constant for ISDs between 1.0 and 3.0 mm, whereas plaque volume measurement variability increased with ISD. Repeated 3D US scan measurements were not different from single-scan measurements (P=0.867). Conclusions-The coefficient of variation in the measurement of plaque volume decreased with plaque size. The volumetric change that must be observed to establish with 95% confidence that a plaque has undergone change is ≈20% to 35% for plaques \u3c100 mm3 and ≈10% to 20% for plaques \u3e100 mm3. Measurement precision was unchanged for ISDs \u3e3.0 mm, whereas measurement variability increased with ISD. Repeated 3D US scans did not affect plaque volume measurement variability

    Pyramidal flux in an anisotropic diffusion scheme for enhancing structures in 3D images

    Get PDF
    Pyramid based methods in image processing provide a helpful framework for accelerating the propagation of information over large spatial domains, increasing the efficiency for large scale applications. Combined with an anisotropic diffusion scheme tailored to preserve the boundaries at a given level, an efficient way for enhancing large structures in 3D images is presented. In our approach, the partial differential equation defining the evolution of the intensity in the image is solved in an explicit scheme at multiple resolutions in an ascending-descending cycle. Intensity 'flux' between distant voxels is allowed, while preserving borders relative to the scale. Experiments have been performed both with phantoms and with real data from 3D Transrectal Ultrasound Imaging. The effectiveness of the method to remove speckle noise and to enhance large structures such as the prostate has been demonstrated. For instance, using two scales reduces the computation time by 87% as compared to a single scale. Furthermore, we show that the boundaries of the prostate are mainly preserved, by comparing with manually outlined edges

    Quantitative 3-D head ultrasound measurements of ventricle volume to determine thresholds for preterm neonates requiring interventional therapies following posthemorrhagic ventricle dilatation

    Get PDF
    Dilatation of the cerebral ventricles is a common condition in preterm neonates with intraventricular hemorrhage. This posthemorrhagic ventricle dilatation (PHVD) can lead to lifelong neurological impairment through ischemic injury due to increased intracranial pressure, and without treatment can lead to death. Two-dimensional ultrasound (US) through the fontanelles of the patients is serially acquired to monitor the progression of PHVD. These images are used in conjunction with clinical experience and physical exams to determine when interventional therapies such as needle aspiration of the built up cerebrospinal fluid (ventricle tap, VT) might be indicated for a patient; however, quantitative measurements of the ventricles size are often not performed. We describe the potential utility of the quantitative three-dimensional (3-D) US measurements of ventricle volumes (VVs) in 38 preterm neonates to monitor and manage PHVD. Specifically, we determined 3-D US VV thresholds for patients who received VT in comparison to patients with PHVD who resolve without intervention. In addition, since many patients who have an initial VT will receive subsequent interventions, we determined which PHVD patients will receive additional VT after the initial one has been performed. (c) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI

    Analysis of carotid lumen surface morphology using three-dimensional ultrasound imaging

    Get PDF
    Carotid plaque surface irregularity and ulcerations play an important role in the risk of ischemic stroke. Ulcerated or fissured plaque, characterized by irregular surface morphology, exposes thrombogenic materials to the bloodstream, possibly leading to life- or brain-threatening thrombosis and embolization. Therefore, the quantification of plaque surface irregularity is important to identify high-risk plaques that would likely lead to vascular events. Although a number of studies have characterized plaque surface irregularity using subjective classification schemes with two or more categories, only a few have quantified surface irregularity using an objective and continuous quantity, such as Gaussian or mean curvature. In this work, our goal was to use both Gaussian and mean curvatures for identifying ulcers from 3D carotid ultrasound (US) images of human subjects. Before performing experiments using patient data, we verified the numerical accuracy of the surface curvature computation method using discrete spheres and tori with different sampling intervals. We also showed that three ulcers of the vascular phantom with 2 mm, 3 mm and 4 mm diameters were associated with high Gaussian and mean curvatures, and thus, were easily detected. Finally, we demonstrated the application of the proposed method for detecting ulcers on luminal surfaces, which were segmented from the 3D US images acquired for two human subjects

    Quantification of carotid vessel wall and plaque thickness change using 3D ultrasound images

    Get PDF
    Quantitative measurements of carotid plaque burden progression or regression are important in monitoring patients and in evaluation of new treatment options. 3D ultrasound (US) has been used to monitor the progression or regression of carotid artery plaques. This paper reports on the development and application of a method used to analyze changes in carotid plaque morphology from 3D US. The technique used is evaluated using manual segmentations of the arterial wall and lumen from 3D US images acquired in two imaging sessions. To reduce the effect of segmentation variability, segmentation was performed five times each for the wall and lumen. The mean wall and lumen surfaces, computed from this set of five segmentations, were matched on a point-by-point basis, and the distance between each pair of corresponding points served as an estimate of the combined thickness of the plaque, intima, and media (vessel-wall-plus-plaque thickness or VWT). The VWT maps associated with the first and the second US images were compared and the differences of VWT were obtained at each vertex. The 3D VWT and VWT-Change maps may provide important information for evaluating the location of plaque progression in relation to the localized disturbances of flow pattern, such as oscillatory shear, and regression in response to medical treatments
    corecore